Fault Codes:
XCMG General E4030
Fault Description:
Bus failure of J1939
Fault Location:
Controller class
Fault Cause:
1. The emergency stop button was pressed (Cummins engine). \ n2. The engine ECM and emergency stop fuse were burned out. \ n3. There was an open circuit or short circuit in the CAN high and CAN low circuits