Fault Codes:Doosan DX150LC-9C E001325-12

Doosan DX150LC-9C Fault Code E001325-12: Complete Diagnostic Guide

What is Doosan DX150LC-9C Fault Code E001325-12?

Fault Code E001325-12 indicates a hydraulic system pressure sensor circuit malfunction, specifically reporting abnormally low voltage from the main pump pressure sensor. This diagnostic trouble code (DTC) is triggered when the Electronic Control Module (ECM) detects voltage readings below the manufacturer's specified threshold (typically below 0.5V) from the main hydraulic pressure transducer.

This code is critical for the DX150LC-9C because the main pump pressure sensor provides real-time feedback to the ECM for load-sensing hydraulic control. When this sensor circuit fails, the excavator's intelligent hydraulic system cannot properly modulate pump output, leading to inefficient operation, reduced performance, and potential component damage from improper pressure regulation.

Common Symptoms

When fault code E001325-12 is active, operators typically experience:

  • Warning light illumination on the instrument cluster with reduced engine power mode engagement
  • Sluggish or unresponsive hydraulic functions, particularly during combined operations (swing with boom movement)
  • Erratic hydraulic performance where attachments move inconsistently or lack normal digging force
  • Engine derate limiting RPM to approximately 1,500-1,800 to protect the hydraulic system
  • Intermittent fault activation that may clear and return, especially during cold starts or temperature changes

Potential Causes

The most common technical failures triggering this code on used DX150LC-9C excavators include:

  • Damaged or corroded pressure sensor connector (prone to moisture intrusion at the main pump mounting location)
  • Failed hydraulic pressure transducer due to internal diaphragm fatigue or electrical component failure
  • Wiring harness chafing where the sensor cable routes near the swing motor or along the boom base (known wear point)
  • Intermittent ground connection at the sensor mounting point due to corrosion or loose hardware
  • ECM internal circuit degradation (less common, but possible in high-hour machines)
  • Low hydraulic oil level causing actual pressure drops that trigger legitimate sensor readings

How to Troubleshoot and Fix Code E001325-12

Step 1: Visual Inspection and Connector Check Begin by locating the main pump pressure sensor (mounted on the main control valve or pump housing). Disconnect the 3-pin connector and inspect for corrosion, bent pins, or moisture contamination. Clean with electrical contact cleaner and apply dielectric grease. On used excavators, this connector frequently suffers from water intrusion due to deteriorated sealing boots.

Step 2: Electrical Testing with Multimeter Using a digital multimeter (DMM), backprobe the sensor harness connector with the ignition ON (engine off). Measure voltage at the signal wire (typically green or yellow). You should read approximately 5.0V reference voltage. Then check ground continuity (less than 1 ohm resistance to chassis ground). If reference voltage is absent or ground resistance is high, trace the wiring harness for damage, particularly where it passes through the swing bearing area—a notorious rub point on this model.

Step 3: Sensor Functionality Test With the sensor disconnected, measure resistance across the sensor terminals. Specifications typically range from 250-350 ohms at room temperature. If readings are infinite (open circuit) or near zero (short circuit), replace the pressure transducer. For intermittent issues common in used machines, perform a wiggle test while monitoring voltage to identify loose connections.

Step 4: Pressure Verification and System Test If electrical testing passes, install a calibrated hydraulic pressure gauge (0-5,000 PSI range) at the test port to verify actual system pressure matches sensor output. Use Doosan diagnostic software (EPOS) to monitor live sensor data while operating hydraulics. Discrepancies indicate sensor calibration drift requiring replacement.

Step 5: Harness Inspection for Used Equipment For excavators with over 5,000 operating hours, thoroughly inspect the entire sensor harness from the ECM to the sensor. Look for insulation wear at cable ties, heat damage near hydraulic lines, and corrosion at bulkhead connectors. Replace suspect harness sections rather than attempting repairs on safety-critical circuits.


Professional Disclaimer: While this guide provides comprehensive troubleshooting procedures, hydraulic system diagnostics involve high-pressure components and complex electronics. Always consult the official Doosan service manual and consider professional assistance from certified technicians for proper diagnosis and repair, especially when working with used excavators that may have undocumented modifications or wear patterns.

Fault Description:

Cylinder 3 Spray misfire Sensor -(P0303)

Fault Location:

Engine system

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp