Fault Codes:Hitachi ZX120-E 11

What is Hitachi ZX120-E Fault Code 11?

Hitachi ZX120-E Fault Code 11 indicates that the oil delivery pressure of Pump 2 is abnormal — meaning the hydraulic system's second pump is operating outside its specified pressure range as monitored by the machine's controller.

The ZX120-E uses a dual-pump hydraulic system managed by the Pump Control Unit (PCU) and the Engine Control Module (ECM). Fault Code 11 is triggered when the pressure sensor signal for Pump 2 falls outside the expected voltage window, typically deviating from the normal 0.5–4.5V operating range defined by Hitachi's control logic.

This fault is critical because Pump 2 supplies flow for swing, boom, and auxiliary circuits. Abnormal delivery pressure directly degrades cycle times, digging force, and overall machine efficiency — and left unresolved, it accelerates wear on the main control valve and pump internals.

Common Symptoms

  • Illumination of the hydraulic warning indicator on the instrument cluster
  • Noticeable reduction in boom lift force or sluggish swing response
  • Engine entering a power derate mode, limiting RPM to protect the hydraulic system
  • Erratic or hunting hydraulic behavior during combined implement movements
  • Fault Code 11 displayed on the monitor panel with a continuous or intermittent alert tone

Potential Causes

  • Faulty Pump 2 pressure sensor — the sensor element degrades over time, particularly in machines with high hours or frequent exposure to hydraulic fluid contamination
  • Damaged or chafed sensor wiring harness — on the ZX120-E, the harness routing near the swing motor and boom foot pin is a known friction point where insulation wears through
  • Corroded or moisture-infiltrated sensor connector — common on used excavators operating in wet or coastal environments
  • Actual low delivery pressure from Pump 2 — worn pump pistons, failed regulator valve, or a blocked high-pressure filter can produce genuine low-pressure conditions that trigger the code
  • PCU or ECM internal fault — less common, but a failed controller input channel can generate a false code even when the sensor and circuit are intact

How to Troubleshoot and Fix Code 11

Step 1 — Retrieve and document the fault. Connect Hitachi's Dr. ZX diagnostic software (or a compatible J1939/CAN interface tool) to the machine's diagnostic port. Record the fault freeze-frame data, including engine RPM, hydraulic oil temperature, and pump output at the time of trigger. Clear the code and note whether it returns immediately or only under load.

Step 2 — Inspect the wiring harness and connector. Locate the Pump 2 pressure sensor on the main pump assembly. On used excavators, this is the first place to look before touching the sensor itself. Visually trace the harness from the sensor back to the PCU, paying close attention to the routing near the boom foot pivot and the undercarriage frame rails — these are the highest-friction zones on this model. Look for chafed insulation, pinch points, and signs of previous field repairs such as taped splices. At the connector, check for corrosion, bent pins, and water ingress. Clean the connector with electrical contact cleaner and apply dielectric grease.

Step 3 — Test the sensor circuit. With a digital multimeter set to DC voltage, probe the sensor signal wire at the PCU connector with the ignition on and engine off. A healthy sensor should read approximately 0.5V at zero pressure. Backprobe the sensor directly and compare. A significant voltage discrepancy between the two measurement points indicates a wiring fault between the sensor and controller. Check reference voltage supply (typically 5V) and ground continuity at the sensor connector; resistance on the ground circuit above 1Ω is cause for concern.

Step 4 — Verify actual pump pressure. If the circuit tests good, connect a calibrated hydraulic pressure gauge (minimum 600 bar / 8,700 psi rated) to the Pump 2 test port. Operate the machine under load and compare the measured delivery pressure against the ZX120-E service specification (typically 320–350 bar at full load). Pressure significantly below specification points to internal pump wear, a failed regulator valve, or a blocked main pressure filter rather than a sensor or wiring issue.

Step 5 — Replace and retest. Replace the confirmed faulty component — sensor, harness section, or pump-side components — using OEM-equivalent parts. After replacement, clear fault codes with Dr. ZX, run the machine through full hydraulic cycles, and confirm the code does not return under load.

Disclaimer: This guide is provided for informational and diagnostic reference purposes only. Hydraulic systems operate under extreme pressure and pose serious injury risk if serviced incorrectly. Always consult a qualified heavy equipment technician or an authorized Hitachi service dealer before performing repairs, particularly on used machinery where prior damage or non-standard modifications may be present. FairTrade Machinery accepts no liability for repairs undertaken based solely on this content.

Fault Description:

The oil delivery pressure of Pump 2 is abnormal

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp