Fault Codes:Hyundai HX220 NL EPFC 129-4
Solution:
1. Check for open circuits or short circuits in the CD-523(#B)-CN-505(#71) lines 2. Check for open circuits or short circuits in the CD-523(#A)-CN-505(#43) lines 3. Check for open circuits or short circuits in the CD-523(#C)-CN-505(#24) lines
Fault Description:
For 10 seconds, the boom retracted and the pilot pressure sensor measured the voltage to be less than 0.3V
Fault Location:
1. Monitor - Pilot pressure display for boom retraction fault 2. Control function -IPC operation failed
FairTradeMachinery
“You Design the Vision. We Handle the Hard Parts.”
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China’s Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.