Fault Codes:Doosan DX150LC-9C E000175-00

Doosan DX150LC-9C Fault Code E000175-00: Complete Diagnostic Guide

What is Doosan DX150LC-9C Fault Code E000175-00?

Fault Code E000175-00 indicates a communication error between the main Electronic Control Unit (ECU) and the instrument cluster display panel on the Doosan DX150LC-9C excavator. This diagnostic trouble code (DTC) signals that the Controller Area Network (CAN bus) has detected interrupted or corrupted data transmission between these critical control modules.

This code is particularly important for the DX150LC-9C because the instrument cluster serves as the primary operator interface, displaying essential machine parameters including hydraulic temperatures, engine RPM, fuel levels, and other active fault codes. When communication fails, operators lose visibility into machine health, potentially leading to undetected issues that could cause costly damage or unsafe operating conditions.

Common Symptoms

When fault code E000175-00 is active, operators typically experience:

  • Blank or flickering instrument cluster display with intermittent gauge readings
  • Multiple warning lights illuminating simultaneously on the dashboard without clear cause
  • Loss of hour meter tracking and operational data logging
  • Inability to access diagnostic menus or service mode through the display panel
  • Erratic gauge behavior, including fuel level, coolant temperature, or hydraulic oil temperature readings jumping unexpectedly

Potential Causes

The most common technical reasons for E000175-00 on used DX150LC-9C excavators include:

  • Corroded or loose CAN bus connectors at the instrument cluster harness (connector C201) or main ECU connection points
  • Damaged wiring harness between the cab and main frame, particularly where the harness passes through the swing bearing area—a known wear point on the DX150 series
  • Failed instrument cluster circuit board due to moisture intrusion or component age
  • Voltage supply issues to the display panel caused by faulty relays or corroded ground connections (G103 ground point common failure)
  • ECU software corruption or version mismatch after improper updates or battery disconnection procedures

How to Troubleshoot and Fix Code E000175-00

Step 1: Visual Inspection and Connector Check Begin by inspecting all CAN bus harness connectors between the instrument cluster and main ECU. On used excavators, focus on connector C201 (behind the display panel) and C104 (at the ECU). Look for green corrosion, bent pins, or moisture. Clean connectors with electrical contact cleaner and apply dielectric grease before reconnecting.

Step 2: Verify Power Supply and Grounds Using a digital multimeter, check for proper voltage at the instrument cluster power supply (should read 24V DC with key on). Test ground point G103 (located under the operator seat) for continuity to chassis ground—resistance should be less than 1 ohm. Poor grounds are extremely common on machines with 3,000+ hours.

Step 3: CAN Bus Communication Testing With Doosan DMS-5 diagnostic software or compatible scan tool, monitor live CAN bus traffic. Check CAN High and CAN Low voltage levels at the instrument cluster connector—should read approximately 2.5V at rest, fluctuating between 1.5V-3.5V during communication. If no fluctuation occurs, trace the harness through the swing bearing pass-through where abrasion commonly occurs.

Step 4: Component Isolation Disconnect the instrument cluster entirely and check if the ECU registers the fault. If the code clears, the cluster or its wiring is faulty. If the code persists, suspect ECU communication circuit failure or corrupted software requiring dealer-level reprogramming.

For used excavators, always inspect harness routing for rubbing points against metal edges, particularly where cables enter the cab and around the swing motor area—these are high-wear zones on the DX150LC-9C.


Disclaimer: This guide provides general diagnostic information for experienced technicians. Always consult the official Doosan service manual for your specific machine serial number and software version. If unfamiliar with electrical diagnostics or CAN bus systems, contact an authorized Doosan service center to prevent further damage to electronic components.

Fault Description:

Engine oil temperature sensor: High physical range inspection of oil temperature -(P0196)

Fault Location:

Engine system

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.