Fault Codes:Doosan DX215-9C E000105-04(P0112)
What is Doosan DX215-9C Fault Code E000105-04 (P0112)?
Fault Code E000105-04 (P0112) indicates an Intake Air Temperature (IAT) Sensor Circuit Low Input condition on the Doosan DX215-9C excavator. This code triggers when the Engine Control Module (ECM) detects an abnormally low voltage signal from the IAT sensor, typically below 0.14 volts, suggesting the sensor is reporting unrealistically cold air temperatures (often below -40°C/-40°F).
The IAT sensor plays a critical role in the DX215-9C's Tier 4 Final/Stage IV emission system. It measures incoming air temperature so the ECM can precisely calculate air density and adjust fuel injection timing, turbocharger boost pressure, and Diesel Particulate Filter (DPF) regeneration cycles. When this sensor circuit fails, the engine cannot optimize combustion efficiency, leading to increased emissions, reduced power output, and potential long-term engine damage.
Common Symptoms
- Check Engine Light (MIL) illuminated on the instrument cluster with stored diagnostic trouble code
- Engine power derate or reduced hydraulic performance, particularly noticeable during heavy digging operations
- Hard starting conditions in cold weather or extended cranking time before engine fires
- Rough idle or irregular engine RPM fluctuations at low throttle positions
- Excessive black smoke from the exhaust during acceleration due to over-fueling from incorrect air density calculations
Potential Causes
The most common technical failures causing this fault code on used DX215-9C excavators include:
- Shorted IAT sensor internal circuit or contaminated sensor element (common after 3,000+ operating hours)
- Damaged wiring harness between the IAT sensor and ECM, particularly at the engine valley routing point where harness abrasion against the intake manifold occurs
- Corroded or moisture-infiltrated connector pins at the IAT sensor plug (two-wire connector near the air intake system)
- Short to ground in the signal wire due to insulation breakdown or pinched wiring during previous maintenance
- Failed ECM internal circuit (rare, but possible on high-hour machines with electrical system history)
How to Troubleshoot and Fix Code E000105-04 (P0112)
Step 1: Visual Inspection Locate the IAT sensor integrated into the intake air duct or manifold. Disconnect the two-wire connector and inspect for corrosion, bent pins, or moisture. On used excavators, check the entire harness routing from sensor to ECM for rubbing points, especially where it passes near hot exhaust components or sharp metal edges.
Step 2: Sensor Resistance Testing Using a digital multimeter (DMM), measure resistance across the IAT sensor terminals. At 20°C (68°F), resistance should read approximately 2,400-2,700 ohms. At 80°C (176°F), it should drop to roughly 300-350 ohms. Values significantly outside this range indicate sensor failure requiring replacement with genuine Doosan part number 2597-1009 or OEM equivalent.
Step 3: Circuit Voltage Testing With the sensor disconnected and ignition ON (engine OFF), backprobe the harness connector. The 5-volt reference wire should show 4.5-5.2 volts, while the signal wire should read near 5 volts (open circuit). If voltage is absent or incorrect, trace wiring for shorts to ground or check ECM connector C128 terminals for damage.
Step 4: Signal Wire Continuity Check Measure resistance between the sensor signal wire and chassis ground—it should read infinite (open circuit). Any continuity indicates a short to ground requiring harness repair or replacement. For used machines, pay special attention to harness sections near the turbocharger heat shield and fuel cooler mounting bracket where insulation commonly fails.
Step 5: Final Verification After repairs, clear codes using Doosan EPOS diagnostic software or compatible scan tool. Run the engine through varying loads and monitor live IAT data—readings should correlate with actual ambient temperature within ±5°C. Perform a regeneration cycle if the machine has been derated to ensure DPF system recalibrates properly.
Disclaimer: This guide provides general diagnostic procedures for informational purposes. Always consult the official Doosan DX215-9C service manual and consider professional diagnosis by certified Doosan technicians, especially for complex electrical issues or warranty-covered machines.
Fault Description:
Air intake temperature: The signal range of the co-current temperature of the pressurized temperature cooler is checked to be low
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.







FAQs
WhatsApp