HOME>>Excavator fault codes>>Doosan excavator fault codes>>DX215-9C E000110-00(P0116)

Fault Codes:Doosan DX215-9C E000110-00(P0116)

What is Doosan DX215-9C Fault Code E000110-00 (P0116)?

Fault Code E000110-00 (P0116) indicates an Engine Coolant Temperature (ECT) Sensor Circuit Range/Performance Problem on the Doosan DX215-9C excavator. This diagnostic trouble code triggers when the Engine Control Module (ECM) detects that the coolant temperature sensor signal is outside the expected range or shows an illogical reading compared to other engine parameters during operation.

The ECT sensor is critical for the DX215-9C's Doosan DL08 engine management system. It provides real-time coolant temperature data that the ECM uses to control fuel injection timing, idle speed, and emission systems. When this sensor circuit malfunctions, the engine cannot optimize performance based on actual operating temperature, potentially causing poor fuel economy, rough idling, or difficulty starting in cold conditions.

Common Symptoms

  • Check Engine Light (MIL) illuminated on the instrument cluster with stored fault code
  • Engine runs excessively rich or lean, resulting in black smoke or poor throttle response
  • Hard starting when the engine is cold, or prolonged cranking before ignition
  • Engine fails to reach normal operating temperature or overheats without apparent cause
  • Cooling fans running constantly at high speed, even when engine is cold

Potential Causes

The most common technical causes for Code E000110-00 on used DX215-9C excavators include:

  • Faulty ECT sensor with internal resistance drift (common after 5,000+ operating hours)
  • Corroded or loose wiring harness connectors at the sensor or ECM (check connector C-117)
  • Chafed wiring along the harness routing near the engine block where vibration causes insulation wear
  • Contaminated coolant causing sensor element fouling or scaling
  • ECM software calibration issues or internal ECM fault (less common)
  • Incorrect coolant mixture affecting sensor accuracy
  • Physical damage to sensor housing from previous maintenance or component replacement

How to Troubleshoot and Fix Code E000110-00 (P0116)

Step 1: Visual Inspection Begin by inspecting the ECT sensor location on the engine block (typically near the thermostat housing). Check for coolant leaks, corrosion on the connector terminals, and physical damage. On used excavators, carefully examine the wiring harness for chafing points where it contacts the engine block or frame—this is a notorious failure point on the DX215-9C.

Step 2: Electrical Testing Using a digital multimeter, disconnect the ECT sensor connector and measure resistance across the sensor terminals. At 68°F (20°C), resistance should read approximately 2,400-2,700 ohms. Compare readings at different temperatures using a temperature/resistance chart. Check harness continuity from sensor connector to ECM pins and verify less than 5 ohms resistance. Inspect for short circuits to ground.

Step 3: Live Data Analysis Connect Doosan diagnostic software (DMS) or compatible scan tool to monitor live ECT sensor data. Compare the ECT reading with Intake Air Temperature (IAT) sensor during cold start—they should read within 10°F of each other. If the ECT shows erratic voltage (jumping between values) or remains static regardless of engine temperature, replace the sensor.

Step 4: Replacement and Verification If testing confirms sensor failure, replace with a genuine Doosan ECT sensor (Part # 65.05603-5003A or equivalent). Apply dielectric grease to connector terminals to prevent future corrosion. For used excavators with high hours, consider replacing the sensor pigtail harness section if any corrosion is present. Clear codes using diagnostic software and perform a cold-to-hot temperature cycle to verify repair.


Disclaimer: This guide provides general troubleshooting information. Always consult the official Doosan service manual for your specific machine serial number and consider professional diagnostic assistance for complex electrical issues or if you lack proper diagnostic equipment.

Fault Description:

Antifreeze temperature: The physical range inspection of antifreeze temperature is high

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp