Fault Codes:Doosan DX220LC-9C E520710-12
Doosan DX220LC-9C Fault Code E520710-12: Complete Diagnostic Guide
What is Doosan DX220LC-9C Fault Code E520710-12?
Fault Code E520710-12 indicates a "Swing Motor Solenoid Valve Circuit - Current Below Normal" condition in the Doosan DX220LC-9C excavator's hydraulic control system. This diagnostic trouble code (DTC) is triggered when the Electronic Control Unit (ECU) detects abnormally low current flowing through the swing motor solenoid valve circuit, typically below the manufacturer's specified threshold of approximately 200-300 milliamps during normal operation.
This code specifically affects the hydraulic pilot control system that regulates swing function operation. The swing motor solenoid valve controls hydraulic oil flow to the swing motor, and when the ECU cannot maintain proper electrical current to this valve, swing performance becomes compromised. For the DX220LC-9C model, this is critical because the proportional solenoid valve directly impacts machine productivity, cycle times, and operator safety during slewing operations.
Common Symptoms
When fault code E520710-12 is active, operators typically experience:
- Erratic or sluggish swing response when rotating the upper structure, with inconsistent swing speeds
- Complete loss of swing function in one or both directions (left/right rotation)
- Warning light illumination on the instrument cluster with possible audible alarm
- Reduced hydraulic pressure to the swing motor, causing the machine to swing slowly under load
- Error message display on the monitor panel specifically referencing the swing system or hydraulic malfunction
Potential Causes
The most common technical reasons for E520710-12 in used Doosan excavators include:
- Damaged or corroded wiring harness between the ECU and swing motor solenoid valve, particularly at flex points near the swing bearing where cables experience continuous movement
- Failed swing motor solenoid valve coil with increased internal resistance or open circuit condition
- Corroded or loose electrical connectors at the solenoid valve or ECU connection points, common in machines with 3,000+ operating hours
- Chafed wire insulation causing short circuits to ground, especially where harnesses contact the swing frame or hydraulic lines
- ECU internal fault affecting the solenoid valve driver circuit (less common but possible in high-hour machines)
- Low battery voltage or poor ground connections affecting overall electrical system performance
How to Troubleshoot and Fix Code E520710-12
Step 1: Visual Inspection and Connection Verification
Begin by disconnecting the battery negative terminal for safety. Locate the swing motor solenoid valve on the main control valve assembly (typically on the right side of the machine). Inspect the electrical connector for corrosion, bent pins, moisture intrusion, or physical damage. On used excavators, pay special attention to the wiring harness routing from the ECU (located in the cab) down to the swing motor valve—check for chafing, cuts, or insulation damage at all flex points and cable ties.
Step 2: Electrical Circuit Testing
Using a digital multimeter (DMM), perform resistance and continuity checks. With the connector disconnected at the solenoid valve, measure the coil resistance across the solenoid terminals—it should typically read between 3-8 ohms (consult the Doosan service manual for exact specifications). Next, check for continuity between each wire and ground; any reading below 10,000 ohms indicates a short to ground. Measure the supply voltage at the harness connector with the ignition on—you should see battery voltage (approximately 24V for this model) on the power supply wire.
Step 3: Component Replacement and ECU Diagnostics
If wiring and connections test satisfactory, the solenoid valve coil itself is likely failed and requires replacement. Before installing new components on used machines, thoroughly clean all connector terminals with electrical contact cleaner and apply dielectric grease to prevent future corrosion. After repairs, clear the fault code using Doosan DMS (Diagnostic Master System) software or compatible diagnostic tool and perform operational testing. If the code returns immediately, suspect an ECU driver circuit failure requiring controller replacement or repair.
Disclaimer: This guide provides general diagnostic information for experienced technicians. Always consult the official Doosan service manual for your specific machine serial number and software version. If you're unsure about electrical diagnostics or hydraulic system repairs, contact a certified Doosan technician or authorized service center to prevent further damage or safety hazards.
Fault Description:
PRV-3 monitoring: Forced opening of the pressure relief valve to implement pressure shock -(P1080)
Fault Location:
Engine system
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.