Fault Codes:Doosan DX220LC-9C E520720-12
What is Doosan DX220LC-9C Fault Code E520720-12?
Fault Code E520720-12 indicates a Boom Raise Solenoid Valve Circuit Malfunction - specifically a short circuit to ground condition in the electrical circuit controlling the boom raise function. This diagnostic trouble code (DTC) is generated when the Electronic Control Module (ECM) detects abnormal current flow in the boom raise solenoid valve circuit, typically caused by damaged wiring that creates an unintended path to ground.
This fault is critical for the DX220LC-9C because it directly affects the excavator's primary lifting capability. The boom raise solenoid controls hydraulic flow to the boom cylinders, and when the ECM detects a short circuit, it may disable the function entirely to prevent component damage or erratic machine behavior. For used excavators, this code often points to wear-related electrical issues rather than component failure.
Common Symptoms
- Boom raise function becomes inoperative or intermittent - the boom may not respond to joystick commands or only works sporadically
- Warning light illumination on the instrument cluster, often accompanied by audible alarm
- Error message displayed on the monitor panel specifically referencing boom circuit or hydraulic system fault
- Reduced machine productivity as operators cannot perform lifting operations safely or efficiently
- Intermittent operation that worsens with machine vibration or specific boom positions, indicating harness damage
Potential Causes
The most common causes of E520720-12 on used DX220LC-9C excavators include:
- Damaged wiring harness along the boom assembly where continuous flexing causes insulation breakdown and wire exposure to grounded metal surfaces
- Corroded or moisture-infiltrated connectors at the boom raise solenoid valve, especially on machines operated in wet or corrosive environments
- Chafed wiring at known rub points near the boom pivot pin area or along the upper structure routing paths
- Failed boom raise solenoid valve with internal short circuit, though less common than harness issues
- ECM connector corrosion affecting the output circuit integrity
- Previous repair attempts using incorrect wire gauge or inadequate insulation restoration
How to Troubleshoot and Fix Code E520720-12
Step 1: Visual Inspection of Wiring Harness Begin by thoroughly inspecting the boom raise solenoid harness from the ECM connection point to the valve itself. On used excavators, pay particular attention to areas where the harness flexes during boom movement or contacts metal edges. Look for abraded insulation, exposed copper wire, or evidence of previous electrical tape repairs. Check all connector pins for corrosion, bent terminals, or moisture intrusion.
Step 2: Electrical Testing with Multimeter Disconnect the boom raise solenoid valve connector and measure resistance between the solenoid circuit wire and chassis ground with the ignition off. You should read infinite resistance (open circuit). Any reading below 10,000 ohms indicates a short to ground. Next, check the solenoid valve itself by measuring resistance across its terminals—typical values range from 8-15 ohms depending on specification. Consult the Doosan service manual for exact values.
Step 3: Isolate the Fault Location If Step 2 confirms a short circuit, systematically disconnect harness sections to isolate whether the fault exists in the main harness, boom-mounted harness, or the solenoid valve itself. For used machines, inspect harness routing clamps—loose or missing clamps allow excessive wire movement and accelerated wear. Use a diagnostic laptop with Doosan G-SCAN software to monitor real-time circuit voltage while manipulating the harness to identify intermittent shorts.
Step 4: Repair and Verification Replace damaged harness sections using OEM-equivalent wire with proper gauge and temperature rating. Ensure all repairs use heat-shrink tubing and proper connector sealing. If the solenoid valve has failed, replace it with a genuine Doosan part to ensure proper ECM communication. After repairs, clear the fault code, cycle the boom raise function multiple times, and verify the code does not return.
Disclaimer: This guide provides general troubleshooting information for educational purposes. Hydraulic and electrical systems operate under high pressure and voltage. Always consult the official Doosan service manual and consider professional diagnostic services, especially for used equipment with unknown maintenance history.
Fault Description:
Common Rail Pressure Monitoring 7: The set point of the measuring device cannot be trusted in the over-run mode -(P1050)
Fault Location:
Engine system
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.







FAQs
WhatsApp