Fault Codes:Doosan DX225LC-9C E000175-00
Doosan DX225LC-9C Fault Code E000175-00: Complete Diagnostic Guide
What is Doosan DX225LC-9C Fault Code E000175-00?
Fault Code E000175-00 indicates a communication error between the Main Controller (PMC) and the Engine Controller (ECM) on the Doosan DX225LC-9C excavator. This code is triggered when the CAN Bus communication network experiences a data transmission failure or complete loss of signal between these critical control modules.
This fault is particularly serious because the PMC (Power Management Controller) relies on continuous data exchange with the ECM (Engine Control Module) to coordinate hydraulic demand, engine load management, and overall machine performance. On the DX225LC-9C, which features Doosan's advanced Smart Power Control system, any disruption to this communication network can severely impact operational efficiency and potentially cause the machine to enter protective shutdown mode.
Common Symptoms
When fault code E000175-00 is active, operators typically experience:
- Engine derating or immediate shutdown as the PMC cannot receive engine status data
- Illuminated warning light on the instrument cluster with possible error message display
- Erratic hydraulic performance including loss of power or unresponsive controls
- Intermittent operation where the machine works normally then suddenly loses power
- Inability to start the engine in severe cases, with the starter engaging but ECM not responding
Potential Causes
The most common technical reasons for E000175-00 on used DX225LC-9C excavators include:
- CAN Bus wiring harness damage from rubbing against the engine block or hydraulic lines (common wear point near the main frame pivot)
- Corroded or loose connector terminals at the PMC or ECM connection points, especially in machines exposed to harsh environments
- Failed CAN Bus termination resistor (120-ohm resistor) causing signal reflection and data corruption
- ECM or PMC internal failure due to voltage spikes, water intrusion, or component aging
- Damaged shielding on the twisted-pair CAN wiring, allowing electromagnetic interference from starter motor or alternator
- Faulty ground connections at controller mounting points creating voltage reference issues
How to Troubleshoot and Fix Code E000175-00
Step 1: Visual Inspection of CAN Bus Harness Begin by inspecting the communication harness running between the PMC (located in the right-side console) and ECM (mounted on the engine). Look for physical damage, abrasion marks, or harness routing that contacts moving parts. On used excavators, check the harness pass-through at the swing bearing area—this is a known friction point on the DX225LC-9C.
Step 2: Check Connector Integrity Disconnect the CAN Bus connectors at both the PMC and ECM. Inspect pins for corrosion, bent terminals, or moisture intrusion. Clean contacts with electrical contact cleaner and apply dielectric grease before reconnection. Ensure locking tabs engage fully—loose connections are a frequent cause on machines with 3,000+ operating hours.
Step 3: Test CAN Bus Resistance Using a digital multimeter, measure resistance across the CAN-High and CAN-Low wires at the ECM connector (with harness disconnected from controllers). You should read approximately 60 ohms with both termination resistors in circuit. A reading of 120 ohms indicates one termination resistor has failed; infinite resistance suggests an open circuit in the wiring.
Step 4: Verify Power and Ground Circuits Check that both controllers receive proper battery voltage (24V nominal) and have solid ground connections. Measure voltage drop across ground paths—it should be less than 0.1V. Clean and tighten ground bolts at controller mounting brackets.
Step 5: Utilize Doosan Diagnostic Software Connect Doosan DMS (Diagnostic Master Software) or compatible diagnostic tool to monitor live CAN Bus traffic. This will identify whether data packets are being transmitted and if error frames are appearing on the network. The software can also perform bi-directional tests to command ECM functions through the PMC.
Step 6: Replace Components as Needed If wiring and connections test satisfactory, suspect controller failure. On used machines, ECM failures are more common than PMC issues. Before replacing expensive controllers, verify the 24V power supply module isn't sending voltage spikes that could damage electronics.
Disclaimer: This guide provides general diagnostic information for experienced technicians. Always consult the official Doosan service manual for your specific machine serial number. If unfamiliar with electrical diagnostics or CAN Bus systems, consult a certified Doosan technician to prevent further damage to electronic components.
Fault Description:
Engine oil temperature sensor: High physical range inspection of oil temperature -(P0196)
Fault Location:
Engine system
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.