Fault Codes:Doosan General E001180-31
What is Doosan Excavator Fault Code E001180-31?
Fault Code E001180-31 indicates a hydraulic pump solenoid valve circuit malfunction with an open circuit or short to ground condition detected by the Electronic Control Module (ECM). This code specifically relates to the main hydraulic pump's electronic proportional control valve, which regulates pump displacement and flow output based on operator demand and load sensing requirements.
This fault is critical for Doosan excavators because the pump solenoid valve directly controls hydraulic system efficiency and machine performance. When this circuit fails, the ECM cannot properly modulate pump output, leading to reduced productivity, excessive fuel consumption, or complete loss of hydraulic functions. The "-31" suffix typically designates an electrical circuit fault rather than a mechanical pump failure, making proper electrical diagnosis essential before condemning expensive hydraulic components.
Common Symptoms
- Warning light illumination on the instrument cluster with fault code display showing E001180-31
- Reduced hydraulic power or sluggish operation across all functions (boom, arm, bucket, swing)
- Engine RPM increase without corresponding hydraulic response due to pump remaining in minimum displacement mode
- Intermittent loss of hydraulic functions that may temporarily restore after key cycling
- Increased fuel consumption as the system cannot efficiently match pump output to demand
Potential Causes
The most common causes for this fault code on used Doosan excavators include:
- Damaged wiring harness between the ECM and pump solenoid valve, particularly at routing points near the pump mounting area where vibration and heat exposure cause insulation breakdown
- Corroded or loose electrical connectors at the pump solenoid valve, especially on machines with high operating hours in wet or corrosive environments
- Failed pump solenoid coil due to internal winding breakdown or contamination from hydraulic fluid ingress
- ECM internal driver circuit failure affecting the solenoid valve control output
- Chafed wires rubbing against the pump housing or mounting brackets—a known wear point on older Doosan machines
- Contaminated connector pins from hydraulic oil mist accumulation in the pump compartment
How to Troubleshoot and Fix Code E001180-31
Step 1: Visual Inspection Begin with a thorough physical examination of the pump solenoid valve harness from the ECM connection through to the pump. On used excavators, carefully inspect areas where the harness passes near sharp edges, rotating components, or heat sources. Look for abraded insulation, melted wire covering, or oil-soaked connectors indicating seal leakage.
Step 2: Connector and Resistance Testing Disconnect the solenoid valve connector at the pump and inspect for corrosion, bent pins, or hydraulic fluid contamination. Using a digital multimeter, measure the solenoid coil resistance (typically 3-8 ohms for Doosan pump solenoids—consult your specific service manual). An open circuit (infinite resistance) or very low resistance (below 1 ohm) indicates coil failure.
Step 3: Circuit Continuity and Short Testing With the connector still disconnected at both the pump and ECM ends, test each wire for continuity and check for shorts to ground. Set your multimeter to continuity mode and verify less than 5 ohms resistance through each circuit wire. Then check each wire to machine ground—any continuity indicates a short circuit requiring harness repair or replacement.
Step 4: Power and Ground Verification Reconnect only the ECM side and turn the key to the ON position (engine off). Using your multimeter, backprobe the pump solenoid connector to verify the ECM is providing proper supply voltage (typically 12V or 24V depending on system) and a good ground reference. If voltage is absent, suspect ECM driver circuit failure or a blown fuse in the control circuit.
Step 5: Solenoid Replacement or Harness Repair Based on your findings, replace the pump solenoid valve if resistance readings are out of specification, or repair/replace the wiring harness if circuit faults are present. For used machines, consider replacing connector terminals even if they appear functional, as internal corrosion may cause intermittent faults. After repairs, clear the fault code using Doosan diagnostic software (DX-Diag or equivalent) and perform a function test under load.
Disclaimer: This guide provides general diagnostic procedures for informational purposes. Hydraulic and electrical system repairs should be performed by qualified technicians with appropriate training and tools. Always consult the manufacturer's service manual for your specific machine model and serial number. Improper diagnosis or repair may result in equipment damage or personal injury.
Fault Description:
The exhaust temperature sensor is faulty
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.







FAQs
WhatsApp