Fault Codes:Hitachi ZH200LC-5A 11403-2
What is Hitachi ZH200LC-5A Fault Code 11403-2?
Hitachi ZH200LC-5A fault code 11403-2 means the current feedback of the solenoid valve unit (SC) for rod regeneration is abnormal. The Main Controller (MC) has detected that the current actually flowing through the solenoid does not match the current it commanded.
The SC solenoid controls arm (rod) regeneration in the hydraulic circuit. Regeneration recirculates return oil to speed up arm movement and reduce pump load. A fault here costs you arm speed and fuel efficiency, and it can slow cycle times on the ZH200LC-5A.
Common Symptoms
- Fault code displayed on the monitor, with a warning indicator active.
- Noticeably slower arm-in speed, especially under light load.
- Longer work cycles and higher fuel consumption than normal.
- Intermittent loss of arm regeneration, often worse when the machine is hot or vibrating.
- Code returns after clearing, which points to a persistent circuit fault.
Potential Causes
- Open or shorted solenoid coil in the SC valve unit.
- Harness chafing, pinched wires, or rodent damage near the control valve and along the boom.
- Corrosion or water ingress in the solenoid connector, common on machines washed or worked in wet conditions.
- Loose or backed-out connector pins at the solenoid or MC.
- Low battery voltage or poor grounds.
- Rarely, an internal fault in the MC output driver.
How to Troubleshoot and Fix Code 11403-2
Step 1: Record and verify the code. Connect Dr. ZX diagnostic software, or use the monitor service menu. Note whether the code is active or stored, then clear it and see if it returns.
Step 2: Inspect visually. On a used excavator, check for previous repairs, taped splices, harness friction and corrosion before replacing any parts. Look closely at the harness near the control valve, clamps and moving sections.
Step 3: Check the connector. Disconnect the SC solenoid connector. Look for green corrosion, moisture, bent pins and loose terminals. Clean with electrical contact cleaner and apply dielectric grease.
Step 4: Test the solenoid coil. Use a multimeter to measure coil resistance and compare it with the Hitachi workshop manual specification. Also check for a short to ground. An open circuit, a short or a reading far out of range means the solenoid needs replacing.
Step 5: Test the harness. With the key off and both ends disconnected, check continuity from the solenoid connector to the MC. Check for shorts to ground or to other wires. Flex the harness while testing to expose intermittent breaks.
Step 6: Check power and grounds. Confirm stable battery voltage and solid ground connections.
Step 7: Confirm the repair. Reconnect everything, clear the code, and run the arm through full cycles. If the code returns with good wiring and solenoid, suspect the MC and test it before replacing it.
Disclaimer: This guide is for general informational purposes. Specifications vary by serial number and software version, so always consult the official Hitachi service manual and a qualified heavy equipment technician before making repairs.
Fault Description:
The current feedback of the solenoid valve unit (SC)(rod regeneration) is abnormal
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.