Fault Codes:Hitachi ZW220 13314-3

What is Hitachi ZW220 Fault Code 13314-3?

Hitachi ZW220 fault code 13314-3 means the driving (service) brake pressure sensor is sending a high-voltage signal to the controller. The signal is above the normal range, which usually points to a short to a power source, an open ground, or a failed sensor.

The brake pressure sensor reports hydraulic brake circuit pressure to the machine controller. The controller uses it to monitor braking performance and coordinate travel functions. The "-3" suffix is the standard failure mode for voltage above normal.

The ZW220 is a wheel loader, not a tracked excavator, but the same diagnostic logic applies to any used Hitachi machine. Left unresolved, the fault can hide a real loss of braking pressure, which is a safety concern.

Common Symptoms

  • Warning lamp or fault message on the monitor display.
  • Brake pressure warning that appears with no real brake problem.
  • Limited travel performance or restricted operation, depending on controller logic.
  • Intermittent fault that comes and goes with vibration or moisture.
  • Fault code that returns right after being cleared.

Potential Causes

  • Failed pressure sensor with internal short or drift.
  • Harness signal wire shorted to the 5V or battery supply.
  • Chafed wiring near the axle, frame articulation point, or clamps.
  • Open or high-resistance sensor ground.
  • Corrosion or water inside the connector.
  • Rarely, a faulty controller input circuit.

How to Troubleshoot and Fix Code 13314-3

Step 1: Inspect before you replace. Used machines often have prior repairs, harness friction, and corroded pins. Check the sensor connector for green corrosion, bent terminals, and moisture. Examine the harness along the frame and articulation area for rub-through.

Step 2: Read and record the code. Use the monitor or Dr. ZX diagnostic software to check whether the code is active or stored. Clear it, then see if it returns immediately.

Step 3: Test the sensor circuit. With the key on and the sensor connected, measure supply, signal, and ground with a multimeter. Compare the readings to the service manual specification. A signal near supply voltage suggests a short to power or an open ground.

Step 4: Isolate the harness. Disconnect the sensor and the controller connector. Check the signal wire for continuity and for shorts to other wires or to the supply. Wiggle the harness while monitoring the meter to catch intermittent faults.

Step 5: Check the sensor. If the harness tests good, replace the brake pressure sensor with a genuine or quality-matched part. Verify the brake system pressure with a gauge to confirm the reading is real.

Step 6: Verify the repair. Clear the code, run the machine, and cycle the brakes. Suspect the controller only after the sensor and wiring are confirmed good.

Disclaimer: This guide is for informational purposes only. Brake systems are safety-critical. Always follow the official Hitachi service manual and consult a qualified heavy equipment technician before performing repairs.

Fault Description:

The driving braking pressure sensor has a high voltage

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp