Fault Codes:Hitachi ZW310-5A 111702-6
What is Hitachi ZW310-5A Fault Code 111702-6?
Fault code 111702-6 on a Hitachi ZW310-5A is a calibration-interruption code: it is stored when the machine controller (ECM) starts an automatic calibration or learning routine and the calibration stop is cut off in the first position — the sequence aborts before a valid zero-point is written to memory.
In practice, the controller commanded a learn cycle for a monitored position circuit — typically the accelerator pedal or a lever position sensor reporting to the ECM over the CAN link — and the routine never reached its first confirmation step. The ECM therefore holds no trustworthy baseline for that circuit and flags it as uncalibrated.
This is critical on this machine because the electronically governed diesel and its hydraulic control depend on that baseline for throttle response, torque matching, and smooth implement movement. Without it, the ECM substitutes a default value and protects the driveline — felt by the operator as a derate.
Common Symptoms
- Warning lamp and stored code on the monitor panel; the code returns immediately after clearing if the routine still cannot complete.
- Engine derate or capped rpm — fuelling is limited because the ECM has no valid calibration reference.
- Erratic accelerator response, hanging idle, or a dead spot in the first part of pedal travel.
- Sluggish, inconsistent hydraulics — slow boom or lift response and uneven travel speed under load.
- Failed calibration attempts — the service routine aborts at step one each time a technician tries to re-learn the circuit.
Potential Causes
- Harness chafe and friction points — the loom between frame and engine, around the articulation joint and battery box, is the classic culprit; insulation rubs through and the signal drops momentarily, aborting the learn cycle.
- Corroded or backed-out connector pins — water ingress at the sensor and ECM connectors shifts resistance and pushes the signal outside the acceptance window.
- Sensor or actuator failure — a worn position sensor with a dead spot at the first position never produces the confirmation the controller expects.
- Low or unstable supply voltage — a weak battery or high-resistance ground drops voltage during cranking and aborts the routine mid-sequence.
- ECM memory or software issue — less common, but a controller that loses adaptive memory on every key-off will re-flag the code.
How to Troubleshoot and Fix Code 111702-6
Step 1 — Retrieve and record the code. Connect Hitachi diagnostic software or a J1939-capable scan tool and read active and stored codes with freeze-frame data. Note voltage at the ECM during the fault; anything below spec invalidates every later test.
Step 2 — Inspect before you meter. Trace the sensor harness by hand from sensor to ECM. Look for rubbed insulation at the frame-to-engine transition, chafed loom near the articulation pivot, and green corrosion or pushed-back terminals in every inline connector. On used excavators and loaders this visual pass finds the fault more often than any meter reading.
Step 3 — Check supply and ground. With a multimeter, verify the reference voltage at the sensor connector, then measure resistance from sensor ground back to battery negative. More than roughly 1 ohm indicates a bad ground.
Step 4 — Test the sensor signal. Sweep the pedal or lever slowly through full travel while watching live data. The signal must rise and fall smoothly, with no dropouts or steps; a jump at the first position confirms sensor replacement.
Step 5 — Repair, then recalibrate. Fix the harness or sensor, clear the code, and run the calibration routine to completion with the machine at operating temperature and a fully charged battery. Confirm the code stays clear through two key cycles and a loaded test.
Disclaimer: This guide is for informational purposes only. Diagnostic procedures and specifications vary by serial number and software version — always consult the official Hitachi service manual and a qualified heavy equipment technician before replacing components.
Fault Description:
The calibration stop is cut off in the first position
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.