Fault Codes:Hitachi ZX200LC-5G 20113-2

What is Hitachi ZX200LC-5G Fault Code 20113-2?

Fault Code 20113-2 on the Hitachi ZX200LC-5G indicates a malfunction in the boom down solenoid valve circuit, specifically detecting an abnormal voltage or open circuit condition. This code is generated when the Electronic Control Module (ECM) detects that the electrical signal to the boom down proportional solenoid valve is outside the expected voltage range or has lost continuity entirely.

This fault directly impacts the hydraulic control system's ability to regulate boom descent operations. The proportional solenoid valve precisely controls hydraulic oil flow to the boom cylinder, and any electrical disruption compromises operator control and machine safety. For the ZX200LC-5G's advanced hydraulic system, maintaining proper solenoid function is critical for smooth operation and preventing uncontrolled boom movements.

Common Symptoms

When fault code 20113-2 is active, operators typically experience:

  • Erratic or complete loss of boom lowering function while other hydraulic functions operate normally
  • Warning light illumination on the instrument cluster, often accompanied by an audible alarm
  • Boom movement becomes jerky or unresponsive when attempting downward operations
  • Reduced hydraulic response or delayed reaction when engaging boom down controls
  • Possible entry into derate mode limiting overall machine performance to protect hydraulic components

Potential Causes

The most common technical causes for code 20113-2 on used ZX200LC-5G excavators include:

  • Damaged wiring harness between the ECM and boom down solenoid valve, particularly at flex points near the boom base where cable fatigue occurs
  • Corroded or loose electrical connectors at the solenoid valve itself, especially on machines with high hour counts or exposure to moisture
  • Failed boom down proportional solenoid valve due to internal coil breakdown or contamination
  • Shorted or open circuits in the valve harness caused by pinching, rodent damage, or insulation deterioration
  • ECM internal fault affecting the solenoid driver circuit (less common but possible on high-hour machines)
  • Poor ground connections at the valve mounting point or main chassis ground

How to Troubleshoot and Fix Code 20113-2

Step 1: Visual Inspection Begin by thoroughly inspecting the wiring harness running from the main ECM (located in the cab area) to the boom down solenoid valve on the main control valve assembly. On used excavators, check specifically for wire chafing at the boom pivot point and along the right-hand side chassis rail where harnesses commonly rub. Examine all electrical connectors for corrosion, bent pins, or moisture intrusion.

Step 2: Electrical Testing Disconnect the solenoid valve connector and use a digital multimeter to check solenoid coil resistance. The boom down solenoid should typically read between 10-30 ohms (consult service manual for exact specifications). Next, test for voltage supply from the ECM with the ignition on—you should see battery voltage when commanded. Check for continuity in all wiring between the ECM connector and valve connector.

Step 3: Component Testing and Replacement If wiring tests pass, connect Hitachi diagnostic software (Dr.EX) to command the solenoid directly and monitor actual versus expected current draw. For used machines, even if resistance reads correctly, internal contamination or worn valve spools may prevent proper operation. Replace the boom down proportional solenoid valve if electrical tests confirm the component fault. After any repairs, clear codes, cycle the boom function multiple times, and verify the fault doesn't return.

Disclaimer: This guide provides general troubleshooting information. Always consult the official Hitachi service manual for your specific machine serial number and seek professional assistance from certified Hitachi technicians for complex electrical diagnostics or hydraulic system repairs.

Solution:

Check the CAN wiring harness.

Fault Description:

System fault alarm

Fault Location:

Monitor controller (monitor) fault code table

Fault Cause:

CAN communication bus failure.

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp