Fault Codes:Hitachi ZX210LCK-5G 11400-4

What is Hitachi ZX210LCK-5G Fault Code 11400-4?

Hitachi ZX210LCK-5G fault code 11400-4 means the main controller has measured a feedback current below 70 mA at the flow-limit P/S (proportional solenoid) valve of hydraulic pump 2 — an open circuit, a failed solenoid coil, or excessive resistance in that valve's control circuit.

On the ZX210LCK-5G, each variable-displacement pump is trimmed by a proportional solenoid mounted on its regulator. The main controller (MC) outputs a PWM command and continuously monitors the resulting coil current, which normally sits in the several-hundred-milliamp range. The -4 suffix flags the low-current side of the diagnostic window.

This matters because the MC uses that valve to limit pump 2 displacement as load rises. Once current drops below 70 mA the controller can no longer trust the valve, so pump 2 defaults to a safe, reduced flow. On a 21-tonne machine that translates straight into lost digging force and mismatched combined operations.

Common Symptoms

  • Fault code 11400-4 stored in the monitor with the hydraulic system warning icon and audible alarm.
  • Noticeable loss of digging power, especially when boom, arm and swing are combined.
  • Pump 2-side functions (one travel side, swing, or boom) feel slow or weak compared with pump 1.
  • Machine may operate almost normally at light load and only derate under heavy demand.
  • Intermittent fault that appears after rain, washing, or rough ground — a classic sign of a chafed wire or wet connector.

Potential Causes

  • Harness damage — the pump-side loom rubs against the regulator bracket and frame rail, a known wear point on high-hour ZX series machines.
  • Corroded or backed-out pins in the solenoid connector after years of moisture and vibration.
  • Open solenoid coil from heat ageing or water ingress into the valve body.
  • Poor ground at the pump frame or a loose harness clamp allowing the wire to flex.
  • Previous repair damage — a poorly crimped splice, wrong-voltage solenoid, or harness left misrouted after a pump swap.
  • MC output driver fault — rare, and only confirmed after everything else checks out.

How to Troubleshoot and Fix Code 11400-4

Step 1 — Retrieve and verify. Pull stored codes with Hitachi Dr.ZX or an equivalent diagnostic tool, clear them, then run the machine and perform a wiggle test on the pump loom. Note whether the code returns immediately or only under vibration.

Step 2 — Inspect physically. Disconnect the pump 2 solenoid connector and inspect for green corrosion, moisture, or pushed-back pins. Trace the harness along the pump and look for rub-through, heat damage, and old repairs hidden under tape.

Step 3 — Measure coil resistance. Key off, measure across the solenoid terminals with a multimeter. Compare directly against the pump 1 valve — on a used machine a known-good reference is worth more than any spec sheet. Infinite resistance means a failed coil.

Step 4 — Check the circuit. Key on, back-probe the connector and command the valve through diagnostic mode. Confirm supply voltage and check continuity end-to-end from the MC pin to the solenoid. Then load-test the wire with a test lamp; a corroded conductor can show 24 V on a meter yet carry no current.

Step 5 — Isolate by substitution. Swap the pump 1 and pump 2 solenoid plugs. If the fault follows the harness, the problem is wiring or the MC; if it stays with pump 2, replace the solenoid.

Step 6 — Repair and confirm. Replace pins or the solenoid, use a sealed splice with correct gauge wire, reroute and clamp the harness clear of moving parts, clear codes, and verify current feedback on the diagnostic screen under load.

This guide is provided for reference only. Always follow Hitachi service literature and safety procedures; consult a qualified heavy equipment technician before replacing controllers or hydraulic components.

Solution:

Check the wiring harness.

Fault Description:

The flow limit P/S valve FB of pump 2 has a small current

Fault Location:

The proportional solenoid valve is faulty

Fault Cause:

Current: Below 70 mA

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp