Fault Codes:Hitachi ZX350H-5G 11400-2

Fault code 11400-2 is a pump-control circuit fault stored by the engine/hydraulic controller on the Hitachi ZX350H-5G. It is a current-feedback fault, not a mechanical failure, so the diagnosis always starts at the wiring and the solenoid — not at the pump.

What is Hitachi ZX350H-5G Fault Code 11400-2?

Fault code 11400-2 means the controller commanded the Pump 2 flow limit P/S (proportional solenoid) valve at 140 mA or above, while the feedback current returned either greater than 920 mA or below 70 mA — both over-current and under-current conditions were detected.

The P/S valve is the proportional solenoid mounted on the regulator of the No. 2 main pump. The ECM drives it with a PWM current to limit pump displacement (flow) according to engine speed, work mode and load, then reads the return current as confirmation. A shorted coil or chafed feed wire pushes feedback far above the command; a broken wire, open coil or high-resistance ground pulls it below the expected value. The log showing both extremes points to an intermittent circuit — typically a harness that makes and breaks contact under vibration.

This matters because flow limiting is what prevents the pump from stalling the engine and over-drawing hydraulic power. A valve stuck at maximum flow causes lugging, black smoke and oil overheating; a valve stuck at minimum flow leaves Pump 2 functions slow and unresponsive.

Common Symptoms

  • Fault code 11400-2 displayed or stored on the monitor panel, sometimes clearing and returning.
  • Noticeably sluggish or uneven boom, arm, bucket and swing speeds, with Pump 2 circuits worst affected.
  • Engine bogging down, stalling under heavy dig loads, or excessive black smoke.
  • Hydraulic oil running hot and reduced fuel efficiency from a fixed-displacement pump.
  • Default limp-home behaviour with reduced power, triggered intermittently by bumps or cold oil.

Potential Causes

  • Harness chafing along the pump compartment and engine frame — rub points at clamps, frame edges and the pump mount are common on high-hour machines.
  • Corroded connectors at the solenoid, the inline harness joint and the ECM pins, usually from washdown and outdoor storage.
  • Solenoid coil failure — open winding, shorted turns or an oil-soaked coil cooked by heat and vibration.
  • High-resistance ground or voltage drop on the return path, producing false feedback readings.
  • ECM driver fault or a previous field repair with a spliced wire or wrong-specification coil — rule these out last.

How to Troubleshoot and Fix Code 11400-2

Step 1 — Retrieve and record. Connect Hitachi diagnostic software (MPDr/WinDR or a compatible tool) to the service port. Note active and stored codes, clear them, then run the machine: an instant return means a hard fault, a return only under vibration means intermittent.

Step 2 — Inspect the circuit physically. Disconnect the batteries and trace the branch from the ECM to the P/S valve. Flex the harness by hand looking for rub-through, crushed sections and oil saturation, and open every connector for green corrosion, pushed-back pins or water ingress.

Step 3 — Measure with a multimeter. Check coil resistance at the valve connector against the workshop manual specification, then test each pin for continuity to ground and insulation to chassis. Back-probe the command wire and compare commanded mA with feedback current; repeat while wiggling the harness.

Step 4 — Repair and verify. Replace the solenoid if the coil is out of specification, and repair harness damage with crimps and heat-shrink — never twist-and-tape. Clear the codes and cycle all hydraulic functions at operating temperature before releasing the machine. On used excavators, always prove the harness and coil before replacing the ECM.

Disclaimer: This guide is for reference only. Always follow the Hitachi workshop manual and safety procedures for your serial number, and consult a qualified heavy equipment technician for final diagnosis and repair.

Solution:

Check the wiring harness.

Fault Description:

The flow limit P/S valve FB of Pump 2 is abnormal

Fault Location:

The proportional solenoid valve is faulty

Fault Cause:

Output of solenoid valve: 140mA or above, feedback current: greater than 920 mA or less than 70 mA; Both were detected.

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp