Fault Codes:Hitachi ZX350LCK-5G 11208-4
What is Hitachi ZX350LCK-5G Fault Code 11208-4?
Hitachi ZX350LCK-5G fault code 11208-4 means the main controller has detected that the signal voltage from the Pump 2 flow control pressure sensor circuit has dropped below 0.1V — an out-of-range low reading caused by an open signal line, a short to ground, or a failed sensor.
The Pump 2 flow control pressure sensor is a three-wire transducer: a 5V reference from the controller, a signal return, and a dedicated ground. It reports regulator (control) pressure, which the MC (main controller) and ECM use to calculate pump displacement and match hydraulic output to engine load. A healthy signal sweeps roughly 0.5–4.5V in proportion to pressure.
Once the signal falls under 0.1V, the controller cannot resolve pump displacement and substitutes a default value. On a 35-tonne class carrier like the ZX350LCK-5G that means pump 2 stops trimming to load — costing cycle time and fuel, and loading pump 1 unevenly.
Common Symptoms
- Fault code 11208-4 stored and displayed on the monitor panel, often with the service icon illuminated.
- Sluggish or uneven combined operations — arm-in/boom-up and swing circuits feel weak or jerky.
- Pump 2 fails to destroke under load; the engine labours or drops toward derate in heavy digging.
- Increased fuel consumption and poor auto-idle / eco mode response.
- No abnormal noise in most cases — the fault is electrical, not mechanical.
Potential Causes
- Harness chafe along the pump deck and frame rails, where loom rubs the pump partition or a clamp — a classic failure point on high-hour used machines.
- Corroded or water-ingressed connector at the sensor, usually after pressure washing or wet-site work.
- Sensor failure — diaphragm rupture or internal short pulling the signal to ground.
- Poor sensor ground or a lost 5V reference shared with other sensors on the same circuit.
- Previous field repair: a bad splice, scotch-lock, or incorrectly pinned connector.
- Blown fuse or, rarely, a faulty controller output.
How to Troubleshoot and Fix Code 11208-4
Step 1 — Confirm with diagnostics. Connect Hitachi Dr.ZX (MPDr) or an equivalent reader and watch live data for the Pump 2 flow control pressure sensor against Pump 1 and a mechanical pressure gauge. A near-zero signal while the gauge reads normal pressure confirms an electrical fault, not a hydraulic one.
Step 2 — Inspect before you test. Trace the harness from the sensor through the pump compartment. On used excavators, look specifically for friction wear, flattened loom, exposed copper, green corrosion in the pins, and moisture in the connector body. Clean with contact cleaner and inspect the seals.
Step 3 — Electrical checks with a multimeter. Key on, engine off, sensor connected: back-probe the 5V reference (should read ~4.8–5.1V), then signal-to-ground. Disconnect the sensor and check ground continuity to battery negative (under 1 ohm) and signal-line resistance end to end. Wiggle the harness while watching the meter — a fluctuating reading exposes an intermittent break.
Step 4 — Isolate the sensor. With a verified 5V supply and good ground, a signal still pinned below 0.1V means the sensor has failed. A missing supply points to the harness or controller. Repair or replace accordingly — do not replace the sensor on a guess.
Step 5 — Clear and verify. Clear the code, run all functions through full cycles, re-read live data, and re-check after a heat cycle to confirm the fault does not return.
Disclaimer: This guide is for reference only. Always follow the manufacturer's service manual and pinout for your serial number, and consult a qualified heavy equipment technician before replacing components.
Solution:
Check the wiring harness. Replace the control pressure sensor of Pump 2.
Fault Description:
The input voltage of the flow control pressure sensor circuit for Pump 2 is low
Fault Location:
Hydraulic pump
Fault Cause:
Voltage: Below 0.1V
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.







FAQs
WhatsApp