Fault Codes:Hitachi ZX450-3 11404-4

What is Hitachi ZX450-3 Fault Code 11404-4?

Hitachi ZX450-3 fault code 11404-4 means the solenoid valve unit (SG), which controls overflow pressure, is reporting a low current anomaly. The main controller (MC) is not seeing the expected current in the SG solenoid circuit, usually because of an open circuit, a poor connection, or a failed coil.

The SG proportional solenoid valve adjusts the pilot signal that sets overflow (relief) pressure in the hydraulic system. The MC drives it with a controlled current and monitors the feedback. If the feedback is too low, the MC flags a low current fault.

This matters on the ZX450-3 because overflow pressure affects pump load, digging force, and fuel efficiency. A faulty SG circuit can cause erratic hydraulic performance and extra heat in the system.

Common Symptoms

  • Warning on the monitor with code 11404-4 logged in the controller history.
  • Weak or inconsistent digging, boom, or arm power.
  • Sluggish or uneven hydraulic response under load.
  • Higher-than-normal hydraulic oil temperature or engine loading.
  • Intermittent fault that appears with vibration or after washing the machine.

Potential Causes

  • Open circuit or high resistance in the SG solenoid harness.
  • Corroded, loose, or water-contaminated connectors at the solenoid valve unit.
  • Failed solenoid coil (open winding).
  • Chafed or broken harness wires at clamps and bend points, common on high-hour machines.
  • Faulty MC output driver (rare, so rule out the other causes first).

How to Troubleshoot and Fix Code 11404-4

Step 1: Read and record the codes. Connect Dr. ZX or use the monitor's diagnostic menu. Note whether 11404-4 is active or only in history. Clear it and see if it returns.

Step 2: Inspect the connectors. Disconnect the SG solenoid connector. Look for green corrosion, bent pins, moisture, and loose terminals. On used excavators, previous wear, harness friction, and corrosion are the most common culprits, so check these before replacing any parts.

Step 3: Test the coil. With the key off and the connector unplugged, measure resistance across the SG coil with a multimeter. Compare it with the specification in the Hitachi workshop manual. An open reading or a large deviation means the coil needs replacing.

Step 4: Check the harness. Test continuity from the solenoid connector to the MC connector, wire by wire. Flex the harness while measuring to expose intermittent breaks. Also check for shorts to ground.

Step 5: Repair and verify. Repair damaged wires with proper splices and sealed connectors. Replace the coil or solenoid valve if it is faulty. Clear the code and run the machine under load.

Step 6: Consider the controller last. If the wiring and coil test good and the code persists, have the MC output checked by a qualified Hitachi technician.

Disclaimer: This guide is for informational purposes only. Hydraulic and electrical diagnostics on heavy equipment can be hazardous. Always follow the official Hitachi service manual and consult a qualified heavy equipment technician before making repairs.

Fault Description:

The solenoid valve unit (SG)(overflow pressure control) feedback a low current anomaly

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp