Fault Codes:Hitachi ZX470H-3 11400-3
What is Hitachi ZX470H-3 Fault Code 11400-3?
Hitachi ZX470H-3 fault code 11400-3 means the Main Controller (MC) has detected an abnormal high-current feedback from the Pump 2 maximum flow limit control solenoid valve circuit. The solenoid, its wiring, or the MC output is drawing more current than commanded.
This solenoid valve is driven by the MC with a controlled current signal. It limits the maximum flow rate of Pump 2 according to work mode and load. If the current is out of range, pump flow can no longer be regulated accurately.
That makes the code critical on a 47-tonne class machine. Pump 2 feeds key functions such as boom, arm, and travel, so poor flow control reduces productivity and can stress the hydraulic system.
Common Symptoms
- Fault code shown on the monitor or stored in the Dr. ZX diagnostic history.
- Reduced or inconsistent Pump 2 flow, with slow boom, arm, or travel speed.
- Weak combined operations, with sluggish response under load.
- Intermittent fault that appears when the machine is hot or vibrating.
- Changes in work mode (power/economy) that do not match the expected performance.
Potential Causes
- Shorted solenoid coil with low internal resistance, caused by heat and age.
- Chafed harness near the pump area or along frame clamps, causing a short to power or between wires.
- Water intrusion and corroded connector pins, which are common on high-hour machines.
- Previous poor repairs, such as twisted splices, wrong terminals, or damaged seals.
- Rarely, a faulty MC output driver.
How to Troubleshoot and Fix Code 11400-3
Step 1: Read and record the code. Connect Dr. ZX, save the fault history, then clear the code. Run the machine and see whether it returns immediately (a hard fault) or only under vibration or heat (an intermittent one).
Step 2: Inspect visually. On a used excavator, check for previous wear before replacing any part. Look for harness friction, melted insulation, previous splices, oil-soaked loom, and green or white corrosion in connectors.
Step 3: Test the solenoid. With the key off, disconnect the solenoid and measure coil resistance with a multimeter. Compare it with the workshop manual specification. Also check for a short to ground, since any reading to ground means the coil has failed.
Step 4: Test the harness. Disconnect the MC connector and check continuity from the solenoid to the MC. Check for shorts to ground, to the 24V supply, and to adjacent wires. Wiggle the harness while measuring to expose intermittent faults.
Step 5: Repair and verify. Replace the faulty solenoid or repair the harness with sealed, properly crimped connectors. Check the valve for contamination or sticking. Only suspect the MC once the coil and wiring pass every test.
Step 6: Confirm. Clear the code and test the machine under load. Monitor the solenoid current in Dr. ZX to confirm normal values.
Disclaimer: This guide is for general information only. Always consult the official Hitachi service manual or a qualified heavy equipment technician before repairs.
Fault Description:
The maximum flow limit control solenoid valve of Pump 2 gives an abnormal feedback of high current
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.