Fault Codes:Hitachi ZX520LCH-3 11400-3
What is Hitachi ZX520LCH-3 Fault Code 11400-3?
Hitachi ZX520LCH-3 fault code 11400-3 means the machine controller (MC) has detected an abnormally high feedback current from the Pump 2 maximum flow limit control solenoid valve. The solenoid circuit is drawing more current than the MC commanded.
This solenoid valve sets the maximum delivery flow of Pump 2 through the pump regulator. The MC monitors the current in a closed loop. If the feedback is too high, it treats the circuit as faulty.
The code matters on the ZX520LCH-3 because flow limiting affects hydraulic power, engine load matching and fuel efficiency. A faulty circuit can cause slow or erratic movement on the functions Pump 2 supplies.
Common Symptoms
- Warning indicator or fault message on the monitor, with code 11400-3 stored in the controller.
- Reduced or limited Pump 2 flow, causing slow boom, arm, bucket or travel speed.
- Weak combined movements, such as sluggish boom-up while swinging.
- Engine bogging or uneven load under heavy digging.
- Intermittent fault that clears and returns, usually from vibration or heat.
Potential Causes
- Short circuit inside the solenoid coil, caused by heat or age.
- Harness chafing or insulation damage, where a signal wire shorts to ground or to another wire.
- Corroded or water-contaminated connectors, common on high-hour machines.
- Damaged wiring near the pump, where vibration and heat wear the loom.
- Faulty MC output driver (rare, so confirm everything else first).
How to Troubleshoot and Fix Code 11400-3
Important for used excavators: check for previous repairs, harness friction, spliced wires and connector corrosion before replacing any part. Past wear is the most common root cause.
- Read and record the code. Connect Dr. ZX diagnostic software. Note whether the code is active or historical, then clear it and see if it returns.
- Inspect the harness visually. Check the path from the pump regulator solenoid to the MC. Look for rubbed insulation, clamps that have worn through, oil-soaked loom and heat damage.
- Check the connectors. Disconnect and look for green corrosion, bent pins, moisture and loose terminals. Clean with electrical contact cleaner and apply dielectric grease.
- Test the solenoid coil. Unplug the valve and measure resistance across the coil with a multimeter. Compare with the service manual specification. A reading well below spec indicates an internal short.
- Test the wiring. With both ends disconnected, check for continuity to ground and for shorts between wires. Any reading that should be open is a harness fault.
- Replace or repair. Replace the solenoid if the coil is shorted. Repair damaged wiring with sealed splices and protect it with new loom and clamps.
- Verify. Clear the code, run the machine through a full working cycle and check Dr. ZX monitor data for stable solenoid current.
Only consider replacing the MC after the solenoid and harness have both tested good.
Disclaimer: This guide is for general informational purposes. Always follow the official Hitachi service manual and consult a qualified heavy equipment technician before repairs. Follow safety procedures when working on electrical and hydraulic systems.
Fault Description:
The maximum flow limit control solenoid valve of Pump 2 gives an abnormal feedback of high current
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.