Fault Codes:Hitachi ZX850-3 13308-2
What is Hitachi ZX850-3 Fault Code 13308-2?
Hitachi ZX850-3 Fault Code 13308-2 is a CAN (Controller Area Network) communication anomaly indicating a loss or degradation of data transmission between two or more electronic control units on the machine's internal network bus.
On the ZX850-3, the CAN bus serves as the backbone communication highway connecting the Engine Control Module (ECM), the Pump Controller, the Monitor Panel (MC), and ancillary control units. Code 13308-2 specifically flags an abnormality detected at a node within this network, meaning one controller is either not receiving expected data frames or is receiving corrupted signals from another.
This is a high-priority fault on a machine of this class. The ZX850-3 relies on continuous inter-controller communication to manage load-sensing hydraulics, engine load matching, and auto-idle functions — all of which degrade or shut down when CAN integrity is lost.
Common Symptoms
- Warning lamp illumination on the monitor panel, often accompanied by an audible alarm at startup or under load.
- Engine derate or power reduction mode — the ECM restricts fuel delivery as a protective response to loss of pump controller feedback.
- Hydraulic performance degradation — sluggish boom, arm, or swing response due to interrupted communication between the pump controller and ECM.
- Erratic or frozen gauge readings on the monitor display, including RPM, coolant temperature, or hydraulic pressure showing implausible values.
- Multiple simultaneous fault codes appearing at once — a classic indicator that the root cause is a communication failure rather than individual component faults.
Potential Causes
- Damaged or chafed CAN bus wiring harness — On the ZX850-3, harness runs near the swing bearing area and along the boom base are known friction points, particularly on high-hour machines.
- Corroded or contaminated CAN bus connectors — Moisture ingress at the ECM connector block or the main junction connectors under the cab floor is common on used units operating in wet environments.
- Incorrect CAN bus termination resistance — A failed or missing 120-ohm terminating resistor at either end of the bus network will cause intermittent or persistent communication faults.
- Failing or failed control unit (ECM, Pump Controller, or MC) — An internal node failure within one controller can corrupt the entire bus, triggering this code on all connected units.
- Loose or improperly seated connector pins — Vibration over time causes pin-back in multi-pin connectors, a frequent finding on excavators with more than 8,000 hours.
- Low or unstable supply voltage — A weak battery, corroded ground strap, or failing alternator causing voltage drops below 11V can disrupt CAN communication.
How to Troubleshoot and Fix Code 13308-2
Step 1 — Read and document all active fault codes. Before clearing anything, connect Hitachi's Dr. ZX diagnostic software (or a compatible J1939 CAN scanner) to the machine's diagnostic port. Record every active and pending code. Multiple simultaneous codes across different controllers strongly confirm a CAN bus-level fault rather than an isolated sensor issue.
Step 2 — Check supply voltage and grounds. Using a digital multimeter, verify battery voltage at the ECM harness connector with the key on. Acceptable range is 11.5V–14.5V. Inspect and clean all main ground straps — from battery negative to chassis, and from chassis to ECM ground points. Voltage drop exceeding 0.3V on any ground circuit is cause for repair before proceeding.
Step 3 — Inspect CAN bus wiring and connectors. With the key off and battery isolated, perform a physical harness inspection from the ECM back through the main trunk to the pump controller and monitor controller. On used ZX850-3 machines, pay particular attention to harness routing near the hydraulic tank, boom foot pins, and cab entry grommets — these are the highest-wear abrasion points. Look for pinched insulation, chafing, moisture intrusion, or green corrosion on connector terminals.
Step 4 — Measure CAN bus termination resistance. With all controllers disconnected, measure resistance between the CAN-High and CAN-Low wires at the diagnostic connector. A healthy two-node terminated network reads 60 ohms (two 120-ohm resistors in parallel). A reading of 120 ohms indicates one terminator is open; a reading near zero indicates a short. Replace or restore the faulty terminator as needed.
Step 5 — Isolate the fault node. If wiring checks pass, disconnect controllers one at a time and re-check bus resistance and fault activity after each disconnection. The node whose removal restores normal bus resistance or clears the fault is the defective unit. For used machinery, always clean and re-seat connectors and retest before condemning a controller — a significant percentage of apparent ECM failures on high-hour machines trace back to connector corrosion alone.
Step 6 — Clear codes and confirm repair. After all repairs, reconnect all units, restore power, and clear fault codes using Dr. ZX. Run the machine through full hydraulic cycles and monitor for code recurrence under load. A single key cycle clearance is insufficient — confirm across a minimum 15-minute full-load operating cycle.
Disclaimer: This guide is intended as a technical reference for qualified heavy equipment mechanics and experienced operators. Diagnostic and repair procedures on the Hitachi ZX850-3 should be performed by trained personnel with appropriate equipment and access to current Hitachi service documentation. FairTrade Machinery recommends consulting a certified Hitachi service technician for all fault code repairs, particularly on used or high-hour machines where multiple underlying issues may be present.
Fault Description:
CAN communication anomaly
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.







FAQs
WhatsApp