Fault Codes:Hitachi ZX850-3 14105-2

What is Hitachi ZX850-3 Fault Code 14105-2?

Hitachi ZX850-3 Fault Code 14105-2 indicates a Communication Terminal Remote Bounce Failure 2 — a detected instability or repeated signal interruption on a secondary remote communication circuit within the machine's control network.

This code is generated when the ECM (Engine Control Module) or main MCU (Machine Control Unit) detects an erratic, bouncing, or intermittently dropping signal on a designated communication terminal. In Hitachi's ZAXIS 850-3 architecture, this typically relates to the CAN bus or serial communication lines connecting remote controllers, sensor nodes, or auxiliary control modules.

The "bounce" designation means the signal is not cleanly open or shorted — it is fluctuating rapidly, which the ECM interprets as a failure condition. On a large-frame excavator like the ZX850-3, reliable communication between modules governs hydraulic output control, pump regulation, and engine load management, making this fault critical to address promptly.

Common Symptoms

  • Warning lamp illumination on the monitor panel, typically the caution or service indicator
  • Intermittent hydraulic response issues, such as sluggish boom, arm, or swing function during operation
  • Engine derate mode activating unexpectedly, limiting RPM or power output to protect the drivetrain
  • Fault code resets temporarily after a cold start but returns under operating temperature or load — a hallmark of a bounce-type communication fault
  • Monitor display anomalies, including frozen readouts or momentary blank screens on the instrument cluster

Potential Causes

  • Corroded or contaminated communication connectors on the MCU or remote module harness — extremely common on used ZX850-3 units operating in wet or muddy environments
  • Harness chafing or pinching at known rub points on the ZX850-3 frame, particularly along the left-side main harness routing near the swing bearing and engine compartment bulkhead
  • Loose or backed-out terminal pins in the multi-pin communication connectors, caused by vibration over high-hour operation
  • Failing or degraded remote module (auxiliary controller or sensor node) generating an unstable output signal
  • CAN bus termination resistor failure, causing signal reflections that the ECM interprets as a bouncing terminal
  • Moisture ingress into sealed connectors due to cracked conduit or damaged sealing grommets on older machines

How to Troubleshoot and Fix Code 14105-2

Step 1 — Read and Document Active Faults with Diagnostic Software
Connect Hitachi's Dr. ZX diagnostic tool or an equivalent compatible interface. Record all active and stored fault codes before clearing. Note whether 14105-2 appears alongside any other communication or sensor codes, as co-existing faults help isolate which communication branch is affected.

Step 2 — Inspect the Communication Harness for Physical Damage
On used excavators, begin with a thorough visual inspection of the main communication harness before any electrical testing. Focus on known chafe points: the routing channel along the lower left frame rail, the area around the hydraulic pump compartment, and anywhere the harness passes through bulkhead grommets. Look specifically for worn insulation, heat damage from exhaust proximity, or evidence of previous repairs such as taped splices that may have degraded.

Step 3 — Check Connector Condition and Terminal Integrity
Disconnect the communication connectors at the MCU and any remote modules flagged by the diagnostic tool. Inspect each connector for corrosion, moisture, or pushed-back terminals. Use electrical contact cleaner and a terminal pick tool to verify pin seating. Measure contact resistance at each pin with a calibrated multimeter — any reading above 0.5 ohms on a signal wire indicates a problem.

Step 4 — Test CAN Bus Termination Resistance
With the ignition off and both termination resistors in circuit, measure resistance across the CAN High and CAN Low lines at the diagnostic port. The expected value is approximately 60 ohms (two 120-ohm resistors in parallel). A reading significantly higher or lower points to a failed termination resistor or a broken bus wire contributing to the bounce condition.

Step 5 — Verify Signal Quality Under Load
If static checks pass, monitor the communication signal dynamically using the oscilloscope function in Dr. ZX or a standalone automotive oscilloscope. A healthy CAN signal shows clean, square-wave transitions. Rounded edges, noise spikes, or voltage levels outside the 2.5V baseline range confirm an active signal integrity issue, narrowing the fault to either a degraded module output or a compromised wire segment.

Step 6 — Replace or Repair the Identified Component
Only proceed to component replacement after the diagnostic steps above confirm a specific failure point. On high-hour used machines, replacing a connector or repairing a harness section resolves this fault in a majority of cases. If the remote module itself is confirmed faulty through isolation testing, replacement and re-initialization via Dr. ZX will be required.

Disclaimer: This guide is provided for informational and diagnostic reference purposes only. Fault code diagnosis and repair on heavy construction equipment should be performed by a qualified heavy equipment technician using manufacturer-approved tools and procedures. Incorrect repairs can result in equipment damage, safety hazards, or voiding of warranty. Always consult the official Hitachi ZX850-3 service documentation and a certified Hitachi dealer for confirmation before undertaking major repairs.

Fault Description:

Communication terminal: Remote bounce failure 2

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp