Fault Codes:Hitachi ZX870LCH-3 11405-4
What is Hitachi ZX870LCH-3 Fault Code 11405-4?
Fault Code 11405-4 on the Hitachi ZX870LCH-3 indicates a low current anomaly detected in the Solenoid Valve Unit (SI), which controls the quick selection of the walking motor displacement.
This code is triggered when the Engine Control Module (ECM) or Machine Control Unit (MCU) detects that the electrical current flowing through the SI solenoid circuit has dropped below the manufacturer's specified threshold. On the ZX870LCH-3, this solenoid governs the two-speed travel system, switching the hydraulic motor between high-speed and low-torque displacement for road travel and low-speed, high-torque displacement for heavy digging or climbing.
This fault is critical because an unresponsive travel motor displacement solenoid can lock the machine into a single travel speed, reduce tractive effort, and in some cases trigger a system derate that limits overall machine performance on jobsite.
Common Symptoms
- The travel speed selector no longer switches between high and low modes — machine is stuck in one travel speed regardless of operator input.
- A warning lamp or fault indicator illuminates on the monitor panel, accompanied by an audible alert.
- Reduced tractive force on grades or uneven terrain, particularly when the machine cannot downshift into the high-torque displacement mode.
- Possible intermittent loss of travel response or hesitation during travel operations.
- Diagnostic trouble code 11405-4 is logged in the MCU fault history, retrievable via Hitachi's Dr. ZX diagnostic software.
Potential Causes
- Open circuit or broken wire in the SI solenoid harness — a frequent failure point on high-hour ZX870 units where the travel motor area harness experiences continuous flexing and vibration.
- Corroded or contaminated connector pins at the solenoid valve body connector or the MCU harness connector, particularly common on machines operating in wet, muddy, or high-humidity environments.
- Failed SI solenoid coil — internal winding breakage causing an open circuit and zero current draw.
- Harness chafing against the undercarriage frame or travel motor housing — a known wear point on the ZX800–870 series where the wiring loom routes near metal edges.
- MCU output driver fault — less common, but a failed driver stage within the control unit can produce a false low-current reading even with a healthy solenoid.
How to Troubleshoot and Fix Code 11405-4
Step 1 — Retrieve and document the fault. Connect Hitachi's Dr. ZX diagnostic software to the machine's diagnostic port. Confirm fault code 11405-4 is active and note whether it is intermittent or continuous. Clear the code and retest to determine if it reappears immediately under travel operation.
Step 2 — Inspect the harness and connectors. On used excavators, begin here before touching the solenoid. Trace the SI solenoid wiring harness from the MCU connector to the solenoid body on the travel motor. Look for visible chafing, pinching, or heat damage, especially where the loom passes near the swing frame and undercarriage. Disconnect both ends and inspect pins for corrosion, bent terminals, or moisture ingress. Clean connectors with electrical contact cleaner and apply dielectric grease on reassembly.
Step 3 — Measure solenoid coil resistance. Using a digital multimeter, measure resistance across the SI solenoid coil terminals with the connector unplugged. Refer to the Hitachi ZX870LCH-3 service manual for the specified resistance value (typically in the range of 10–30 Ω for pilot solenoids of this class). A reading of OL (open line) confirms a failed coil. A reading within spec shifts focus back to the wiring or MCU.
Step 4 — Perform a voltage and continuity check. With the harness reconnected and the ignition on (engine off), use a multimeter or the Dr. ZX live data function to verify that the MCU is commanding output voltage to the solenoid circuit during a travel speed change request. Confirm continuity end-to-end through the harness. Any break in continuity confirms a wiring fault that must be repaired or the affected section of the harness replaced.
Step 5 — Replace confirmed faulty components. If the solenoid coil is open, replace the SI solenoid valve unit with a Hitachi OEM or approved equivalent. If the fault persists after solenoid and harness repair, escalate to MCU diagnostics with a qualified Hitachi dealer, as an internal MCU driver failure requires controller-level testing or replacement.
Disclaimer: This guide is intended for informational purposes and to assist qualified heavy equipment mechanics and technicians. Always consult the official Hitachi ZX870LCH-3 service and repair manual and follow all relevant safety procedures before performing diagnostics or repairs. If you are unsure of any step, seek assistance from a certified Hitachi dealer or licensed heavy equipment service professional.
Fault Description:
The solenoid valve unit (SI)(quick selection of the walking motor) reports a low current anomaly
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.