Fault Codes:Kobelco SK130-8 B064

What is Kobelco SK130-8 Fault Code B064?

Kobelco SK130-8 Fault Code B064 indicates a short circuit in the power supply circuit of the bucket tipping pressure sensor. This means the ECM (Engine Control Module) has detected an abnormal voltage condition — typically an unexpected high-voltage or dead short — on the 5V reference or signal feed line connected to the bucket tip pressure sensor.

The bucket tipping pressure sensor monitors hydraulic pressure in the bucket curl circuit, feeding real-time data to the MCM (Machine Control Module) to optimize hydraulic output and load management. On the SK130-8, this sensor is integral to the machine's intelligent hydraulic control system (CLSS — Closed-center Load Sensing System).

A short circuit on this circuit can corrupt pressure data, causing the control system to make incorrect flow or relief decisions. Left unresolved, this fault can accelerate hydraulic component wear and trigger cascading fault codes.

Common Symptoms

  • Illumination of the caution warning lamp on the monitor panel, often accompanied by an audible alarm at startup or during operation
  • Reduced hydraulic performance in the bucket curl function, including sluggish or inconsistent bucket response
  • The machine may enter a hydraulic derate mode, limiting pump output to protect the system
  • Erratic or frozen bucket pressure readings when viewed through the Dr. EX diagnostic software monitor screen
  • Fault code B064 logged in the controller fault history, sometimes appearing alongside related codes such as B063 or B065

Potential Causes

  • Short circuit in the sensor harness — the signal wire or 5V supply wire has chafed against the machine frame, boom, or arm cylinder, grounding the circuit. On the SK130-8, the harness routing along the boom is a known friction point.
  • Failed bucket tipping pressure sensor — internal sensor failure causing the supply pin to short to ground or to the sensor body
  • Corroded or contaminated connector — moisture ingress into the sensor connector (typically a 3-pin Deutsch or AMP connector) creates a low-resistance path between supply and ground pins
  • Damaged wiring at the MCM connector — pin back-out, spread terminals, or insulation breakdown at the main controller harness connector
  • MCM internal fault — in rare cases on high-hour machines, the internal driver circuit within the MCM itself fails, falsely pulling the reference voltage low

How to Troubleshoot and Fix Fault Code B064

Step 1 — Read and Document the Fault
Connect Kobelco's Dr. EX diagnostic software (or a compatible CAN-based scan tool) via the machine's service port. Record all active and stored fault codes. Note whether B064 is active or historical, and check for related pressure sensor codes on other circuits.

Step 2 — Inspect the Sensor and Connector
Locate the bucket tipping pressure sensor on the bucket cylinder circuit, typically mounted on the control valve block or the bucket curl line. Disconnect the connector and visually inspect for corrosion, moisture, bent pins, or discolored terminals. On used SK130-8 machines, pay particular attention to harness condition along the boom — look for worn insulation where the cable bundle passes over boom pivot points or contacts metal edges.

Step 3 — Measure the Supply Voltage and Circuit Resistance
Using a calibrated multimeter, with the connector disconnected from the sensor, switch the ignition to ON. Measure voltage between the 5V supply pin and ground at the harness side. Expected reading is 4.75–5.25V. A reading below 1V indicates the supply wire is shorted to ground in the harness. Measure resistance between the supply wire and chassis ground — a reading below 10 kΩ confirms a short to ground.

Step 4 — Isolate the Short in the Harness
With the ignition OFF and the MCM connector unplugged, re-measure resistance between the supply pin at the sensor connector and ground. If the short is still present, the fault lies in the wiring between those two points, not in the MCM. Conduct a physical pull-test along the entire harness run to find the damaged section. Repair or replace the affected harness segment using correct-gauge wire and sealed, heat-shrink splices.

Step 5 — Replace the Sensor if the Harness is Intact
If wiring checks pass, substitute a known-good bucket tipping pressure sensor and retest. Clear the fault code using Dr. EX and cycle the ignition. Confirm the fault does not return under normal operating conditions.

Step 6 — Inspect the MCM as a Last Resort
If the fault persists after harness repair and sensor replacement, inspect the MCM connector for pin damage and test the reference supply directly at the controller. MCM replacement or reconditioning should only be considered after all external causes are eliminated.

Important Note for Used Excavator Owners: On second-hand SK130-8 machines, always inspect harness condition and connector integrity before ordering replacement sensors or controllers. Previous repairs, unauthorized weld work near harness runs, or accumulated grime in connectors are frequent root causes that are easily overlooked.

Disclaimer: This guide is intended as a technical reference for qualified heavy equipment mechanics and experienced operators. Diagnostic procedures on hydraulic and electrical systems carry inherent risks. Always follow Kobelco service manual procedures and applicable safety standards. If you are unsure at any step, consult a certified Kobelco dealer or licensed heavy equipment technician before proceeding.

Fault Description:

The power supply of the bucket tipping pressure sensor is short-circuited

FairTradeMachinery

You Design the Vision. We Handle the Hard Parts.

Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.

As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.

facebookyoutubeinstagramtiktoklinkedinreddit
Contact us
Contact us
faqsFAQsWhatsAppWhatsApp