What is Kobelco SK480LC-8 Fault Code R174?
Fault code R174 on a Kobelco SK480LC-8 means the Engine Control Module (ECM) has detected an abnormal condition in the engine forced stop relay circuit — the relay coil drive, its output contacts, or the feedback signal is outside the manufacturer's expected range.
The forced stop relay is the ECM-controlled switch that interrupts the fuel/stop-solenoid command so the engine can be shut down immediately: on key-off, by the safety shutdown logic, or by the anti-restart strategy. The ECM energises the coil and watches the circuit for a plausible return voltage. An open coil, a short to ground or battery, or excess resistance breaks that plausibility check and latches R174.
On the SK480LC-8's Hino common-rail engine this is not a nuisance light. The relay sits on the same shutdown path as the stop solenoid and starting logic, so a failure can produce a no-shutdown condition — a genuine runaway and safety risk — or an intermittent no-start.
Common Symptoms
- Engine warning lamp on, with R174 stored or active on the machine monitor.
- Engine fails to stop when the key is turned off, or cuts out abruptly and roughly.
- Intermittent crank-no-start, or the engine stalls seconds after starting.
- Audible relay chatter from the relay box, or a relay that runs hot.
- Reduced power/derate on some software versions; restart blocked until the code is cleared.
Potential Causes
- Relay failure — burned contacts or an open/shorted coil from heat and vibration.
- Corrosion on the relay base and pins inside the relay box behind the cab, a known moisture and dust trap on used -8 machines.
- Harness chafe at the engine-to-frame transition near the pump compartment and battery box, where the loom is flexed constantly.
- Loose or oxidised ground (earth) points at the frame and engine block.
- Previous field repairs — splices, scotch-locks, an incorrect relay — and, rarely, a failed ECM driver.
How to Troubleshoot and Fix Code R174
Step 1 — Baseline the fault. Read codes with Kobelco/Hino diagnostic software or the monitor service mode, note freeze data, verify battery voltage (24 V) and check the fuses feeding the stop circuit. Clear the code and re-run to establish whether it is hard or intermittent.
Step 2 — Inspect the relay. Remove it and check the pins for green corrosion, burning or pushed-back terminals. Measure coil resistance with a multimeter and compare against a known-good relay; check contact continuity when energised.
Step 3 — Load-test, don't just ohm. Back-probe the coil feed for 24 V key-on, confirm ground-side continuity, then perform a voltage-drop test while cranking. Wiggle the harness at the known rub points and watch both the meter and the code status.
Step 4 — Repair and verify. Replace corroded terminals, solder and heat-shrink any chafed wire, fit the correct OEM relay, clear codes, then cycle start/stop at least three times.
On used excavators, always inspect for previous wear and tear, harness friction and connector corrosion before condemning any component — most R174 faults are wiring, not the ECM.
This guide is for reference only. Confirm procedures against the Kobelco service manual and consult a qualified heavy diesel technician before replacing major components.
Fault Description:
The engine forced stop relay is abnormal
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.