Fault Codes:Sumitomo SH260LC-6 560
What is Sumitomo SH260LC-6 Fault Code 560?
Fault code 560 on a Sumitomo SH260LC-6 signals abnormal system voltage — the machine's control unit has detected that its 12V power supply has fallen below, or risen above, the range the controller needs to operate reliably.
The SH260LC-6 manages engine and hydraulic matching through an electronic control module (ECM) that continuously watches its own feed: battery positive through the fusible link and main relay, and the return path to chassis ground. Code 560 is logged when measured voltage strays outside the normal band — typically below roughly 10V under cranking or heavy load, or above about 15V while charging.
This matters because the controller and every sensor on the machine share that 12V reference. Low voltage drifts sensor signals, weakens solenoid current and can push the ECM into a protective derate; high voltage stresses the same electronics. On a working machine it shows up as lost hydraulic power, not just a warning light.
Common Symptoms
- Code 560 stored on the monitor panel, often clearing and returning on its own.
- Slow cranking or hard starting, particularly from cold.
- Intermittent engine derate or sluggish hydraulic response under load.
- Monitor screen flickering, dimming or resetting when a function is engaged.
- Batteries flattened overnight, or a charging warning light staying on.
Potential Causes
- Corroded or loose battery terminals and chassis ground straps — the most common cause on older machines.
- Alternator wear: a failing regulator overcharges past 15V, worn brushes and diodes cause low output.
- Main relay and fusible link contact pitting, producing intermittent voltage drops.
- Harness rub points at the cab pivot, battery box edge and along the boom foot, where vibration chafes insulation.
- Water ingress into connectors after pressure washing, causing green corrosion and pin tension loss.
- Aged batteries with a collapsed cell, or an internal ECM supply fault.
How to Troubleshoot and Fix Code 560
Step 1 — Test the battery and charging system. With a multimeter, check static battery voltage (should hold around 12.6V), voltage during cranking (above 9.5V), and charging voltage at fast idle (13.8–14.5V). Anything above 15V points straight at the alternator regulator.
Step 2 — Perform a voltage drop test. Measure from battery positive to the ECM supply pin, and battery negative to the ECM ground, while the circuit is loaded. More than about 0.5V drop means resistance in the cable, relay or ground — not a failed controller.
Step 3 — Inspect the harness and connectors. On used excavators, check for harness friction, chafed insulation and corrosion before replacing any part. Unplug the main connectors, look for green deposits or heat discolouration, and confirm pin tension.
Step 4 — Verify the main relay and fusible links. Substitute a known-good relay and check links for pitting; these fail intermittently and mimic a controller fault.
Step 5 — Clear and retest. Use Sumitomo diagnostic software or the monitor panel service menu to clear code 560, then run the machine under load. If it returns with a clean, stable supply, suspect the ECM itself.
This guide is general technical information only. Confirm procedures and specifications against the official Sumitomo service manual, and consult a qualified heavy diesel technician before replacing major components.
Fault Description:
Abnormal system voltage (12V)
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.