Fault Codes:Sumitomo SH380LHD-6 1113
What is Sumitomo SH380LHD-6 Fault Code 1113?
Sumitomo SH380LHD-6 fault code 1113 means the ECM has detected a high signal voltage — an open circuit or excessive resistance — in the inlet air temperature sensor circuit that reads boosted air temperature after the turbocharger and aftercooler.
The sensor is an NTC thermistor threaded into the intake air pipe or aftercooler outlet. The ECM feeds it a regulated 5V reference through an internal pull-up resistor, and the sensor's resistance varies inversely with air temperature. Cold air produces high resistance and a high signal voltage; hot air produces low resistance and low voltage.
Code 1113 sets when the signal circuit stays above the calibrated maximum (roughly 4.7–4.9V) for the full debounce period, which the ECM interprets as an open sensor or broken wire rather than a genuine temperature reading.
This matters because the ECM combines post-boost air temperature with boost pressure to calculate air density and therefore injection quantity and timing. A missing signal forces a default value, which distorts fuelling, raises exhaust temperature, and can trigger a torque derate on a machine already working at high load.
Common Symptoms
- Diagnostic or check-engine lamp illuminated, often with a stored code and no other obvious complaint.
- Power derate or reduced hydraulic output under load, particularly in high ambient temperatures.
- Black smoke and over-fuelling because the ECM substitutes a fixed low air-temperature value and injects too much fuel.
- Elevated exhaust gas temperature and higher fuel consumption over a shift.
- Rough running, unstable idle, or hard cold starting when the substitute value is far from actual ambient.
Potential Causes
- Harness chafing at the engine-to-frame transition, behind the aftercooler pipe, and where the engine harness passes the exhaust heat shields — common rub points on high-hour -6 series machines.
- Corroded, water-filled, or pushed-back pins in the sensor connector after pressure washing or years of heat cycling.
- Sensor failure — cracked thermistor body or an internal open from vibration and thermal fatigue.
- Open sensor ground or a high-resistance ground path back to the ECM.
- Poor previous repair — a soldered splice or non-OEM sensor fitted by an earlier owner.
How to Troubleshoot and Fix Code 1113
Step 1 — Verify with live data. Connect the Sumitomo diagnostic tool and read inlet air temperature with the engine cold and key on. It should read close to ambient; a fixed extreme value (e.g. –40°C) confirms an open circuit. Record the freeze-frame before clearing anything.
Step 2 — Inspect physically. Trace the harness from the sensor to the ECM, flexing it by hand while watching live data. Look for chafe marks, heat-hardened insulation, green corrosion, and loose pins. On used machines, always check for old splices and non-original sensors before condemning the ECM.
Step 3 — Test the sensor. Disconnect the connector and measure resistance across the sensor pins with a multimeter; compare against the shop manual's NTC table (typically around 2.5 kΩ at 20°C, falling to roughly 0.3 kΩ at 80°C). An open or wildly out-of-range reading means replacement.
Step 4 — Test the circuit. Key on, engine off, back-probe the signal wire: with the sensor unplugged you should see approximately 5V, and with it connected a value between 0.5V and 4.5V. A constant 5V with the sensor fitted confirms an open signal wire. Check sensor ground resistance to battery negative — under 1 Ω — and test for shorts to voltage.
Step 5 — Repair and confirm. Repair chafed wiring with a sealed splice and heat shrink, replace damaged connectors, then clear the code and run the engine to operating temperature with a load applied. Re-check live data after a heat soak to confirm the fault does not return.
Disclaimer: This guide is general technical information only. Always follow the manufacturer's service manual and safety procedures, and consult a qualified heavy diesel technician before replacing components or operating a machine with an active derate.
Fault Description:
The inlet air temperature sensor system has a high input after pressurization
FairTradeMachinery
You Design the Vision. We Handle the Hard Parts.
Helping Global Buyers Access Better-Value Machinery and After-Sales Solutions.
As China's Leading Global Used Machinery Exchange Platform, we sits at the intersection of IoT technology and B2B commerce. That means real-time inventory data, verified seller profiles, and a transaction process designed for cross-border buyers who can't always inspect machines in person. Our users in China have exceeded 1.5 millions meaning we have the first source of excavator owners and the equivalent number of machines. This means we can cover all the popular models and even specific needs, no matter of the status.